NOTICE:
To avoid noise and external interference that may hinder
communication between the reader and the controller/PC, avoid passing
the Wiegand communication cable/flap near sources, lamp reactors,
electrical power cables, or other electromagnetic noise sources.
8.6 Electrical connections - Digital input (Sensor)
The digital input of the reader has the following electrical characteristics:
1KV RMS Opto-Isolated Input;
Supports dry contact circuit, NPN and PNP;
Minimum pulse width: 100ms;
High Level (3,0 a 24,0VCC);
Low Level (0 a 2,0VCC);
Maximum voltage in NPN and PNP: 24VCC;
The digital input can be accessed via the "SENSOR INPUT" connector of the PCI card
Interface, below follows the descriptions of the signals of the digital inputs.
PCI
Connector
Pino
Função
SENSOR
INPUT
ISO_GND
Reference (common) for sensors with dry contact output
DI_COM
Reference (common) for sensors with NPN or PNP output
DI_IN
Isolated digital input #1
Below are examples of sensor connections in the digital input of the reader.
Sensor with dry contact output
(lens)
Sensor with PNP output
(Sourcing)
Sensor with PNP (Sinking)
output
Pinos ISO GND e ISO IN
Pinos ISO COM e ISO IN