reader;
● Fixed memory consumption ERROR in the RS232 serial sending
function.
3.2.3
04/2017
• Fixed ERROR in the IPV4LL generation algorithm in the events of
disconnecting and connecting a network cable;
• Fixed ERROR in the formation of the reading command that uses the
Select mask (ID Filter);
• Small changes aimed at improving the stability of the reader's
operation;
• Added an RF time off with new Ascii command "TMRFOFF";
• Implemented logic to disable the reset button check, through a new
Command Ascii "ENHRDRST";
• Fixed ERROR in the need check logic for rebooting in network
settings;
● Fixed ERROR in Hybrid read mode where a secure tag was reported
with the secure id and then followed by the normal id of the same
secure tag. Only the secure id is now reported.
3.1.9
02/2017
• Fixed BUG in keepalive String generation timer after the reader
exceeds 18 hours of operation;
• In the temperature compensation logic, one more condition was
included, if the temperature is greater than 81°C, it is idle for 5s.
• Improved logic of RF duty cycle, rfon/rfoff;
• Fixed ERROR in zero-value comparations in the Set commands of
TMFTDB, FTSMTG, SELFTDG;
• Changed delay scheme between tags in the transmission of id, now
this delay is configurable by the command ascii DELAYTX from 0 to
500ms, is not on the html page, default of 100ms, before there was
no delay in the RS232 interface which generated errors in some
controllers when it was read but of a tag at the same time;
• Changed to EEPROM memory all the reader settings, so if in future
versions there is the addition of new variables, the firmware update
will not cause the return of the factory values of the other
configuration variables;
• Implemented auto generation ip link local address IPV4LL, where the
factory default IP is empty and the ASsigned IP is 169.254.MAC. mac
with the last two decimal numbers of the MAC address;
• Added keyword "ALIVE" in the data string and keepalive in order to
send the reader uptime in seconds;
• Removed popup from page html Security when changing the autoid
security code, when changing and then clicking the Apply button,
gave the false impression of having saved.
3.1.5
09/2016
● The RS232 interface now only works with LOGIC OR other Wiegand
and Abatrack interfaces, so if you're using Wiegand or Aba, the
RS232 TX won't work;
● Implementado o modo Híbrido de funcionamento, onde hora le tag
Normal hora le tag Seguro;
● You no longer need to restart the reader after changing Autoid Mode;
● One more keyword "TYPE" is included in the data string that sends
the letter "S" when the tag is secure and "N" when it is normal;
● Changed the reading htm page to show all configs if the modo seja
Híbrido;