User's Guide
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid
Rev. 13
Copyright © 2022 Acura Technologies
10 de 92
1
03/2015
• Creation of this document.
4.2 Readers firmware table
Revision
Month/ye
ar date
Description
3.4.7
04/2021
● Fixed ERROR in the safe mode tag verification algorithm when two
readers with different security codes stood side by side, close to each
other, improper readings occurred.
3.4.6
09/2020
● Fixed excessive memory consumption error when the reader was in
Client mode. In this mode, after a period the reader no longer
responded to the ASCII configuration commands.
3.4.5
07/2020
1. Added one more parameter "*" for the commands "OUTPUT0" and
"OUTPUT1", whose function is to exchange the state of the specific
output for a time(s) specified in "OUTPUT0PERIOD" and
"OUTPUT1PERIOD";
2. Added the commands "OUTPUT0PERIOD" and "OUTPUT1PERIOD"
to determine pulse time when "*" is passed as a parameter in
"OUTPUT0" and "OUTPUT1";
● Added the commands "OUTPUT0TAG" and "OUTPUT1TAG", whose
function is to trigger a pulse in the respective outputs for each tag
reading, obeying the time configured in "OUTPUT0PERIOD" and
"OUTPUT1PERIOD".
3.4.4
10/2019
● Fixed algorithm ERROR at startup and RF driver scan.
3.4.2
04/2019
● Fixed ERROR in the javascript of the network configuration page,
where an error message was generated in changing the value of the
communication and configuration ports.
3.4.1
03/2019
• New Ethernet mode as client, it is now possible to choose the
behavior of the reader, such as Server (legacy mode until then) and
as Client mode where a server port and ip must be configured.
• The connection attempt is every 3s in Client mode, the commands
sent to the reader configuration port are interpreted by the same
connection in Client mode.
● Added 3 more commands "ETHMODE" "SVIPADDR" "SVPORT".
3.3.1
02/2019
• Added the option to set a fixed Site Code value for the Wiegand
interface.
• Two new commands accessible only via port 9090 have been
created.
● Created command "ENFXSC" and "VALFXSC", to enable and setar
value, respectively.
3.2.8
07/2018
● Fixed ERROR in the filter algorithm when the read mode chosen was
the hybrid.
3.2.5
05/2017
1. Changes aimed at improving the stability of the functioning of the