Specifications
Configuring the DataBridge SDR2-CF SDR2-CF/SDR2-OEM-CF Configuration Guide rev 1.0
20
Messages are stored as ASCII text strings in non-volatile memory. To use
messages, first enter a text string for one of the ten messages. Then,
configure whether the message should be sent on when recording starts,
when recording stops, or at an interval specified in seconds. The SDR2-CF
can also be configured to append a carriage return
<CR> and/or line feed
<LF> to any message.
To enter a new message, type 5 at the main menu prompt to enter the Edit
Messages submenu. To edit a message, type 1. When prompted, enter the
desired message number (0-9) and type a message followed by the
<Enter> key
.
Figure 2.10. Changing message zero to “$1RD”.
Setting message parameters
To change a message’s parameters, type 2 at the menu prompt. When
prompted, enter the desired message number (0-9) and type a message
followed by the <Enter> key
.
Output intervals: The SDR2-CF sends a message, then waits a specific
amount of time before sending the message again. When configuring a
message, you are prompted to enter this period, or output interval. For
instance, if the message should be output once every ten seconds, type 10
and press the <Enter> key. To disable a message (but leave its contents
intact), enter 0.