The HNLS11 is designed to mount to a standard switch box mounted flush to the wall surface.
A box with a minimum depth of 3-1/2” is required. The Steel City “CX” series is recommended.
Installation Steps:
1. Refer to the wiring diagrams on the other side of this sheet to determine appropriate connections for
the project.
2. Connect supply wires to driver input wires (A) per wiring diagram.
3. Remove and discard nuts holding screws (C) to LED unit and faceplate (B). Do not separate LED unit
from faceplate.
4. Apply silicone sealant to gasket on back of faceplate.
5. Set LED unit (B) in box and align holes in faceplate to holes in box.
6. Thread screws (D) through faceplate and LED unit, securing fixture to switchbox.
7. Align holes in faceplate (C) over holes in LED unit (B).
8. Thread screws (D) through faceplate & LED unit securing fixture to switchbox.
Maintenance & Cleaning:
No regular maintenance is required. The LED module & driver are non-serviceable components with a 50,000
hours operating life to 70% initial output. At 100,000 hours light output will be approximately 50% of initial.
Clean the fixture with a soft cloth moistened with mild soap and water.