7.3 Current Consumption
All testing done at 20C and 3.3V input. 2.4GHz radio in power down unless specified.
Parameter
Symbol
Min
Typ
Max
Unit
Receive Current
I
rx
TBD
mA
Module Sleep Current
I
sleep
TBD
uA
Receive Current with
Beaconing
I
rx+ble
TBD
mA
Max Power SubGhz TX
I
TX200
TBD
mA
Mid Power SubGhz TX
I
TX100
TBD
mA
Low Power SubGhz TX
I
TX0
TBD
mA
Max Power BLE TX
1
I
TX100BLE
Mid Power BLE TX
1
I
TX50BLE
Low Power BLE
TX
1
I
TX0BLE
1
2.4GHz radio is powered up and transmitting, 915MHz radio is in receive mode
7.4 Radio Parameters
7.4.1 SubGhz
7.4.1.1 Power Level Measurement
All testing done at 20°C on channel 7 (916MHz).
Input
Voltage RF Power level
TX Setting: 200
100
0
1.8
14.1
7.4
-2.67
1.9
14.6
7.91
-2.2
2
15.1
8.3
-1.87
2.1
15.5
8.58
-1.67
2.2
15.9
8.76
-1.55
2.3
16.3
8.86
-1.51
2.4
16.6
8.91
-1.5
2.5
16.9
8.92
-1.51
2.6
17.1
8.92
-1.51
2.7
17.4
8.93
-1.54
2.8
17.6
8.95
-1.53
2.9
17.9
8.96
-1.52