I - 2 General Operations for 200S
Remote Switch
The remote switch sets the parameters so the external switch
(pendant, or foot switch) can be enabled to perform any or all of the
following functions: Data Output; Zero, and Next Hole. Refer to
Section II for information on connecting remote switches via
Grounding Edge Finder input.
Data Output - to send position information out of the serial port or to
print the current position.
Zero - to zero one or more axes. In Distance-To-Go mode, it will zero
the Distance-To-Go display. In Actual Value mode, it will zero the
datum).
Next Hole key press will move to the next hole within a pattern (i.e.
Hole Pattern).
8 While in the Data Output Field, press the ON/OFF soft key to ON
to send the current position over the serial port when the switch
is closed.
8 While in the Zero Field, press the appropriate axis keys to enable
or disable zeroing of the axis display positions when the switch is
closed.
8 While in the Next Hole Field, press the ON/OFF soft key to ON to
move to the next hole within a pattern.