Specifications

Mounting options can be adapted to machine mounting surfaces
using spacers, standoffs, or leveling set screws.
Measuring length and mechanical configuration of your machine
determine your options.
Backup spar mounting is an option but not required for lengths
up to 60”.
Fastener lengths described on this page are included with the
encoder or the backup spar.
Less than 24” : Use end mounting holes. Over 60” : A backup spar is required.
7 ACU-RITE
®
ENC150 Mounting Requirements
1/4-20 x 1” BHCS
& scale washer (supplied)
End hole mounting
1/4-20 x 1/2” BHCS
& spar washer (supplied)
Backup spar mounting
24” to 60” : Use end mounting holes with center support.
.94 [23.8]
1/4-20 x 1” BHCS
Typical (supplied)
1/4-20 x 3/4” SHCS
Scale
washer
Center support
End hole mounting
with center support
M4 x 8mm SHSS
(supplied)
Support washer