Specifications

Use this information to plan your Linear Encoder installation.
Mount the linear encoders close to machine guide ways to ensure
system accuracy.
One side of the linear encoder addresses flush mounting surfaces,
and the opposite side addresses offset mounting surfaces.
If space between the reading head and the mounting surface
exceeds .18”, use a spacer or mounting bracket to reduce space.
ACU-RITE bracket kit instructions provide step by step installation
procedures.
Tolerances of .010” TIR apply to all mounting dimensions.
Center support mounting surface required for 24” through 60”
linear encoder measuring lengths mounted without a spar.
Allow clearance for alignment bracket removal.
Alignment brackets must not be removed until
instructed.
Use reading head leveling set screws when surfaces are not flush.
Reading head bracket required for a space >.18”.
ACU-RITE
®
4
Mounting Information ENC150
Flush
mounting
Offset
mounting
Backup spar
mounting
Move bracket past
the cable strain relief
Alignment bracket removal clearance
1.0
[25mm]
1.38
[35mm]
Alignment
bracket
Alignment
bracket
Scale case
-A- = Machine Travel
Reading head
Equal Equal
1.876 .010 [47.6]
0.0 ± .010
//
.010 A
//
.010 A
//
.010 B
// .010 A
//
.010 A
B