Specifications

These steps apply to all spar mounting conditions.
ACU-RITE bracket kit instructions supercede this
section.
Adjust drill depths and fastener lengths as required.
When instructed on page 12: Adjust the leveling set screws
as follows:
1. Insert, but do not tighten 8-32 (M4) reading head screws.
2. Place a .001”-.003” shim between the leveling set screws and
mounting surface.
3. Adjust each set screw until a slight drag is felt on the shim.
4. Evenly tighten the 8-32 (M4) reading head mounting
screws.
Contact your Authorized ACU-RITE Distributor should you
require additional assistance.
Move the axis to its center of travel.
Mark the axis for quick return to center.
Determine encoder cable exit direction and adjust (see page 3).
Drill / tap the first end mounting hole / attach the spar.
Align to within .010” TIR. to -A-, drill / tap second end hole.
Attach the spar / align to within .010” TIR. to -A-.
Locate the spar with the underside flush with the axis parting line.
Mark one end mounting hole location.
11 ACU-RITE
®
ENC150 Spar Installation Procedure
Center
mounting
axis
Mark
center of
axis
C
L
Align to within .010” TIR of -A-
Align top of spar to
within .015” of -A-
-A- = Axis travel
Axis parting line
-A- = Axis travel
1/4-20 x 1/2” BHCS &
Flat washer .017” thk.
End mounting hole (typical)