Specifications

Drill / tap the first end mounting hole / attach the linear encoder.
Align to within .010” TIR. to -A-, drill / tap second end hole.
Attach the linear encoder / align to within .010” TIR. to -A-.
Center the axis and mark the reading head mounting holes.
Move axis, drill / tap holes for 8-32 (M4).
Attach head to axis / Set leveling screws / Secure fasteners.
Use the center support(s) when provided.
Place supports at equal intervals along the encoder’s length.
Center support
1/4-20 x 1” BHCS & Scale flat washer (M6 x 25mm)
Align to within .010” TIR to -A-
Drill / tap
for 1/4-20 (M6).
8-32 x 3/4” SHCS
(M4 x 20mm)
Drill / tap for 8-32 (M4)
ACU-RITE
®
10
Encoder Installation Procedure ENC 150
1/4-20 x 3/4” SHCS
(M4 x 20mm)
-A- = Axis travel
-A-
Flat washer (M6)
Do not tighten prior to adjusting leveling set screws
Slide the brackets away from the reading head.
Remove the alignment brackets and save for future use.
Proceed to page 13, “Checking Your Installation”.
Alignment bracket removal
Slide brackets away from reading head and cable.
Twist 45°