Specifications

These steps apply to all encoder mounting conditions, if a spar is
being used, go to “Spar Installation Procedure” on page 11.
ACU-RITE bracket kit instructions supercede this
section.
Adjust drill depths and fastener lengths as required.
When instructed on page 10: Adjust the leveling set screws
as follows:
1. Insert, but do not tighten 8-32 (M4) reading head screws.
2. Place a .001”-.003” shim between the leveling set screws and
mounting surface.
3. Adjust each set screw until a slight drag is felt on the shim.
4. Evenly tighten the 8-32 (M4) reading head mounting
screws.
Contact your Authorized ACU-RITE Distributor should you
require additional assistance.
Align the center marks on the reading head and scale assembly by
sliding the reading head and brackets along the case.
Locate the scale case so underside of end caps are flush with the
axis parting line.
Mark one end mounting hole location.
Move the machine axis to its center of travel.
Mark the axis for quick return to center.
Configure the encoder cable exit direction (see page 3).
9 ACU-RITE
®
ENC150 Encoder Installation Procedure
Scale case
Reading head assembly
Alignment
brackets (2)
C
L
Center mounting axis
Mark center of travel
C
L
Align top of scale case to
within .015” of -A-
-A- = Axis travel
Cable assembly
Endcap
Scale case
Axis parting line
End mounting hole (typical)
Center marks