Instructions for use Cold Rush® Cold Therapy System
.....................................................................3 EN FR ES Instructions for use.................................................5 Guide de fabrication................................................10 Instrucciones para el uso........................................
EN - Caution: This product has been designed and tested based on single patient usage and is not recommended for multiple patient use. If any problems occur with the use of this product, immediately contact your medical professional. FR- Attention: Ce produit a été conçu et testé pour être utilisé par un patient unique et n'est pas préconisé pour être utilisé par plusieurs patients. En cas de problème lors de l'utilisation de ce produit, contactez immédiatement un professionnel de santé.
1 D A E F B C G 3 2 2 1 3 MAX 4 5 6a 6b
7 8 9 2 1 MAX 10 2 MAX 1 2 MAX 1 2 1 4 MAX
ENGLISH Safety precautions • READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE OPERATING THE COLD RUSH COLD THERAPY SYSTEM. • Correct temperature range for each patient’s skin should be determined on an individual basis by a licensed healthcare practitioner. Patients vary in sensitivity to cold. Periodically monitor the temperature and appearance of the skin being treated once steady flow of water through the pad is achieved.
• • When using while awake, patients must check their skin every 1-2 hours once steady flow of water through the pad is achieved. Turn the flow control knob counterclockwise to increase the temperature (warmer), and clockwise to decrease the temperature (colder). When turning the unit on, turn the flow control knob clockwise to the number “3” setting wait 10 minutes to allow the temperature to stabilize before making any additional temperature adjustments.
• • • • • • • • removing the power supply from wall socket. Avoid getting water or ice on the flow control panel or power adapter. Always unplug this product immediately after each use. Do not use while bathing. Do not place or store product where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid. Do not reach for a product that has fallen into water. Unplug immediately.
4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. line. (Figure 4) Attach the provided 12V power supply to DC power port, do not plug into wall circuit (Figure 5). Apply insulation barrier over the patient’s skin in the area to be treated. (Figure 6a) Apply Cold Rush Pad over insulation barrier. The Cold Rush Pad should never be applied directly over the patient’s skin. (Figure 6b) Connect Cold Rush pad to hose extending from the unit. To ensure proper connection, push couplings together until they snap into place.