User Manual

Auto-ignition temperature
> 626 °F (> 330 °C)
Decomposition temperature
> 572 °F (> 300 °C)
Viscosity
Not available.
10. Stability and reactivity
The product is stable and non-reactive under normal conditions of use, storage and transport.
Reactivity
Material is stable under normal conditions.
Chemical stability
No dangerous reaction known under conditions of normal use.
Possibility of hazardous
reactions
Avoid temperatures above 210 °C. Heat, flames and sparks. Extremes of temperature and direct
sunlight.
Conditions to avoid
Strong oxidizing agents.
Incompatible materials
Carbon dioxide, carbon monoxide, and unburned hydrocarbons.
Hazardous decomposition
products
11. Toxicological information
Information on likely routes of exposure
Inhalation
Health injuries are not known or expected under normal use.
May cause an allergic skin reaction.
Eye contact
Direct contact with eyes may cause temporary irritation.
Ingestion
Not applicable under normal conditions of use. May cause gastrointestinal irritation if ingested.
Symptoms related to the
physical, chemical and
toxicological characteristics
May cause an allergic skin reaction. Dermatitis. Rash. Direct contact with eyes may cause
temporary irritation.
Information on toxicological effects
Acute toxicity
May cause an allergic skin reaction.
Test ResultsConstituents Species
Toxicological data
.BETA.-PINENE (CAS 127-91-3)
Dermal
Acute
LD50 Rabbit > 5000 mg/kg
Oral
LD50 Rat 4700 mg/kg
2,6-DI-TERT-BUTYL-P-CRESOL (CAS 128-37-0)
Dermal
Acute
LD50 Rat > 2000 mg/kg, 24 hours
Oral
* Estimates for product may be based on additional component data not shown.
LD50 Rat > 6000 mg/kg
Prolonged skin contact may cause temporary irritation.
Skin corrosion/irritation
Direct contact with eyes may cause temporary irritation.
Serious eye damage/eye
irritation
Respiratory or skin sensitization
ACGIH sensitization
TURPENTINE AND SELECTED MONOTERPENES
(CAS 127-91-3)
Dermal sensitization
Respiratory sensitization
Not classified.
May cause an allergic skin reaction.
Skin sensitization
No data available to indicate product or any components present at greater than 0.1% are
mutagenic or genotoxic.
Germ cell mutagenicity
Carcinogenicity
This product is not considered to be a carcinogen by IARC, ACGIH, NTP, or OSHA.
4 / 7
Material name: GP PRO ActiveAire® Powered Whole-Room Freshener Dispenser Refill, Coastal Breeze
5518 Version #: 02 Revision date: July-11-2018 Issue date: April-16-2016
SDS US