Instructions / Assembly
7
SYMPTOM CAUSE SOLUTION
The pump does not run Power is not turned on
Incorrectly plugged in
Bound impeller
Turn on the power
Plug in correctly
Remove foreign matter from impeller
The motor repeats ON/OFF
without running pump. It stops
and does not restart
Wrong voltage
The water intake or outlet pipe
is clogged with foreign matter
Correct voltage
Clean out the intake and outlet
The pump runs with reduced or
no performance
Wrong frequency
Impeller worn out
Low water level
Correct frequency
Replace impeller
Ensure the pump is fully submerged
The pump runs normally at the
beginning but the water flows
sluggishly or there is no water
Hose is too long or clogged
Air in the impeller chamber
Shorten hose and/or clean out
To get rid of air, put pump into the
water. Turn the switch to “ON” and “OFF”
intermittently to clear air from pump
TROUBLESHOOTING GUIDE
0
2
4
6
8
10
12
0 200 400 600 800 1000 1200
HEAD (FT) HEIGHT
GALLONS PER HOUR (LPH) VOLUME
AAPW1000
800
550
160
40
400
Pump Gallons Recommended
Model Per Hour Reservoir Size
AAPW1000 1110 100+ Gallon
AAPW800 793 80 Gallon
AAPW550 529 55 Gallon
AAPW400 370 40 Gallon
AAPW250 291 25 Gallon
AAPW160 171 15 Gallon
AAPW40 43 5 Gallon
Active Aqua Submersible Pump Comparison Chart