User`s manual
The Wireless Connectivity Expert
ACT-IR224UN
User’s Manual
© Copyright 2005-2010 ACTiSYS Corp
Page 9 of 34
Jul 15, 2010
Version 1.2.0
7 MIGRATION FROM OTHER MODELS
If you use RS232-based IR adapters or ACT-IR204UN, and now are in migrating to ACT-IR224UN,
you need to know the following details:
¾ When insert ACT-IR224UN CD in Windows, Configuration Utility software will be automatically
installed. (Note: for Mac, Linux users, still need to pre-set all in Windows beforehand.)
¾ Please select the appropriate Model using configuration utility.
Note: For Volume Orders
You may inform us IR adapter model in use, and we can pre-set it for you at factory, so you
don’t need to configure at your site. Your P/O can use one of these model names:
z ACT-IR224UN-LN96 z ACT-IR224UN-L+
z ACT-IR224UN-LN19 z ACT-IR224UN-JE-pulse
z ACT-IR224UN-LN38 z ACT-IR224UN-JE-level
z ACT-IR224UN-LN57 z ACT-IR224UN-IF-pulse
z ACT-IR224UN-LN115 z ACT-IR224UN-IF-level
z ACT-IR224UN-Li
7.1 For ACT-IR220LN Series Users
Select ACT-IR220LN as your adapter model using Configuration utility. Then select baud rate
directly from this Utility. (Note: Baud rate is fixed). Your customized application doesn’t require any
change. Make sure your application supports virtual COM Port. Some application cannot handle
COM Port greater than 4 or 9. Such application needs to be updated.
7.2 For ACT-IR220Li, ACT-IR220L & ACT-IR220L+ Users
Select appropriate model as your existing adapter model name using Configuration utility. Your
customized application doesn’t require any change. Make sure your application supports virtual
COM Port. Some application cannot handle COM Port greater than 4 or 9. Such application needs
to be updated.
7.3 For ACT-IR204UN Users
When opening the COM Port (with specified baud rate), ACT-IR204UN will set the same baud rate
of COM Port to IR communication module whereas ACT-IR224UN
will set the baud rate to the COM
Port only
and not to the IR communication module. Application must use DTR & RTS signal in
virtual COM Port to set IR communication baud rate, in addition to Virtual COM port baud rate. For
baud rate setting details, please refer to Chapter of "Detailed Description for Models" in Technical