User manual
Page 6© 2013 Active Research Limited
The Actisense NMEA Buffer (NBF-3) distributes up to six identical data streams from a single source. Signals are
buffered to ensure each receiver has the required voltage levels. Isolation on the input and each output allows non-
isolated devices to be connected safely. The ability to power the source device allows the option of a single cable to
connect both power and data to the source device.
Features
• Works automatically with any serial protocol, including NMEA 0183
• Works automatically at any baud rate up to 115200 Baud
• Galvanic opto-isolation on the input meets the latest NMEA 0183 specication
• ISO-Drive™ provides galvanic isolation on the outputs to prevent ground loops
• Compatible with all NMEA 0183 versions without requiring conguration
• Inputs and outputs compatible with RS422 and RS232 devices
• DIN rail mountable
• Pluggable screw terminals for quick and easy installation and diagnostics
• Power and data input indicator LEDs
• Amplication of weak input signals
• Power feed for single cable installation to the NMEA Talker
• Waterproof electronics and splash proof connections
Product Overview
Optional power feed
500mA max
Latitude
50˚74’03”
Longitude
-1˚94’95”
Listeners
Talker
Latitude
50˚74’03”
Longitude
-1˚94’95”
12v
Figure 1 - Example of a Typical NBF-3 Installation
Note: Not to be used as wiring instructions