User manual

Page 6© 2013 Active Research Limited
The Actisense NMEA Buffer (NBF-3) distributes up to six identical data streams from a single source. Signals are
buffered to ensure each receiver has the required voltage levels. Isolation on the input and each output allows non-
isolated devices to be connected safely. The ability to power the source device allows the option of a single cable to
connect both power and data to the source device.
Features
Works automatically with any serial protocol, including NMEA 0183
Works automatically at any baud rate up to 115200 Baud
Galvanic opto-isolation on the input meets the latest NMEA 0183 specication
ISO-Drive™ provides galvanic isolation on the outputs to prevent ground loops
Compatible with all NMEA 0183 versions without requiring conguration
Inputs and outputs compatible with RS422 and RS232 devices
DIN rail mountable
Pluggable screw terminals for quick and easy installation and diagnostics
Power and data input indicator LEDs
Amplication of weak input signals
Power feed for single cable installation to the NMEA Talker
Waterproof electronics and splash proof connections
Product Overview
Optional power feed
500mA max
Latitude
50˚74’03”
Longitude
-1˚94’95”
Listeners
Talker
Latitude
50˚74’03”
Longitude
-1˚94’95”
12v
Figure 1 - Example of a Typical NBF-3 Installation
Note: Not to be used as wiring instructions