Specifications

VSBC-6862 Rev 1.43
26
Position 4
VME Reset Out Factory seting Description
Unplugged X Board is not authorized to generate a VME Reset
Plugged-in Board in Slot1 mode is authorized to generate a VME Reset
Description: When this jumper is plugged, if the board is in Slot1 mode, it will generate a VME
Reset when the board is under Hardware Reset.
Position 5
VME Reset In Factory setting Description
Unplugged X VME Reset is not connected to board Reset
Plugged-in VME Reset generates a board Reset when not in Slot1 mode
Description: When this jumper is plugged, if the board is not in Slot1 mode, a VME Reset will
generate a board Hardware Reset.
Position 6
VME Slot1 function Factory setting Description
Unplugged X The VME Slot1 functions are disabled
Plugged-in The VME Slot1 functions are enabled
Description: This jumper defines if the Slot1 function for VME bus is enabled or disabled.
When the Slot1 function is enabled, the board activates the functions to be the
VME System Controller: Arbiter, Clock generation, Daisy-Chain Handling, Bus
timer
Warning
Activate the Slot1 function only if the VSBC-6862 is physically installed in the first
VME Slot.
3.5. Jumper: J3
This jumper is only used for debug purpose.
Figure 9: Jumper J3 location
Warning
It must not be connected without explicit instruction from ACTIS Computer.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com