Specifications

16 Chapter 4
LEAP Login setting, LEAP credentials must be entered at least once before they can
be used for automatic LEAP login.
When the Automatic LEAP Login setting is changed from enabled to disabled, LEAP
credentials previously saved in the permanent storage of the thin client will be deleted.
Load New Firmware (LNF) utility
LNF facilitates updates of Aironet adapter firmware and works in conjunction with the
Aironet FW Add-on. Be aware of the following:
The firmware image must be in the Winterm™ 3 series Add-ons format released by
Wyse Technology.
It is recommended that you install the Aironet FW Add-on either automatically through
Rapport or manually through Add-on Installation from the thin client.
Do not install the Aironet FW Add-on through a DHCP automatic upgrade.
Once the firmware image is used to upgrade the Aironet adapter successfully, the
corresponding Aironet FW Add-on will be removed from the thin client automatically.
Depending on user settings, firmware upgrades can be done manually or automatically:
For manual firmware upgrades, users can click Load New Firmware in the Cisco
Aironet Wireless setup.
For automatic firmware upgrades:
a. Ensure that the Automatic Load New Firmware setting found in the Cisco Aironet
Wireless Setup - Client Configuration dialog box is enabled (default).
b. Install the desired Aironet FW Add-on either automatically through Rapport or
manually through Add-on Installation from the thin client.
c. Restart the thin client with the Aironet adapter plugged in.
d. New firmware loads to the Aironet adapter after the thin client reboots (when the
Aironet driver is loaded).
AutoPower 1.0
Wyse AutoPower 1.0 allows Winterm™ 3 series Thin Clients to automatically boot to CE
.NET without having to use the thin client power button. This Add-on was designed for
customers who installed their thin client in such a way that the power button is
inaccessible to the end user (as the thin client would be rendered inoperable if the thin
client was ever to lose power in such cases as power-outages and so on).
By installing this Add-on, whenever the thin client is physically removed from a power
source (for example pulling the cord from the wall) and the power source is reapplied
(Cold Boot), the thin client will automatically boot to CE .NET without having to use the
thin client power button.
Wyse AutoPower also changes the existing Shut Down mechanism and Power Button
feature of CE .NET so that the thin client never turns off. Therefore, using the Shut Down
command button in the Connection Manager or using the thin client Power Button while in
CE .NET restarts the thin client.
Note
Wyse AutoPower supports models 3125SE, 3230LE, and 3235LE only.