Specifications

57
Hardware Specifications: SERIMUX 16 and SERIMUX 32 DC Powered
Attribute Value
Operating temperature 40°F to 120°F (5°C to 50°C)
Storage temperature -20°F to 140°F (-29°C to 60°C)
Humidity 10% to 90% non-condensing
Power supply Internal 36 - 72 Vdc, 1.2A (max)
Power consumption 0.25A /48Vdc, 12W (typical), 40W (max)
Fuse (internal) FUSE (Type L) AC250V, 2A
Operating system Linux Hard Hat embedded
SDRAM 64 megabytes
Flash memory 8 megabytes
Size (In.) WxDxH: unpackaged 17 x 8.5 x 1.75
Size (In.) WxDxH: packaged 20.375 x 15.25 x 4.75
Weight: unpackaged 5.8 lbs (2.63 kilograms)
Weight: packaged 8.6 lbs (3.9 kilograms)
Hardware Specifications: SERIMUX 8 AC Powered
Attribute Value
Operating temperature 40°F to 120°F (5°C to 50°C)
Storage temperature -20°F to 140°F (-29°C to 60°C)
Humidity 10% to 90% non-condensing
Power supply External 100 - 240VAC, 50/60 Hz, 1.0A (max)
Power consumption AC input: 0.05A /120VAC, 6W (typical), 12W (max)
DC input: 0.8A/5VAC, 4.5 W (typical), 8W (max)
Operating system Linux Hard Hat embedded
SDRAM 64 megabytes
Flash memory 8 megabytes
Size (In.) WxDxH 9.5 x 6.25 x 1.25
Weight 2.5 lbs (1.13 kilograms)
LED Indicators
Use the LED indicators to confirm attachment to the network and that the SERIMUX is able to send and receive data.
LED Function
Power On when power is supplied
Ready On when system is ready to run
System
PC On when a PC device is running
100Mbps On when 100Base-TX connection is detected
LINK On when connected to an Ethernet network
Ethernet
Act Blinks when there is activity on the Ethernet port
In Use On when the serial port is ready to run
Serial
port
Rx/Tx Blinks when there is traffic on the serial port
About Serial Port Cabling
The SERIMUX simplifies cabling. The RJ45 8-pin configuration matches all SUN and Cisco RJ45 console port configurations,
enabling CAT 5 cabling without pinout concerns. Three DB-25 and one DB-9 adapters come in the package. A DB-25 male, a DB-
25 female, and a DB-9 adapter support console management applications. A DB-25 male adapter provides a modem
connection. See the cable adapter information that follows later in this chapter.
Note: The cable length restrictions common to RS-232 cables apply to the SERIMUX serial cable as well.