Figure 62- Configure Slave ports on the Master Unit
.4. Select Enable from the "Enable/Disable this unit" drop down menu.
A new configuration screen appears.
Figure 63- Enable a Slave unit and setup the port information
5. Enter the IP address of the slave unit in the IP address field.
6. Select the Auto Config button and the Master SERIMUX automatically imports the configuration of the Slave serial ports to the
Master SERIMUX. The following figure displays serial port configuration imported from a slave unit.
7. Choose Save & apply.
Clustering Parameters
Below is a list and brief description of clustering parameters:
Enable: This shows whether the port is enabled or disabled. All ports are enabled by default.
• Source port: This is the port number on the master unit.
• Destination port: The destination port is the corresponding port number on the slave unit. On a 32-port slave unit, the
destination port numbers range from 7001 to 7032.
• Protocol: The four options are N/A (not available), SSH, Telnet, and RawTCP.
Base source port: This sets the first port number on a master unit. By default the base source port on the master unit
is 7001. However, the user can change the base source port number to another number and the
rest of the ports on the unit will be sequentially numbered from the base source port. For example,
starting the base source port number with 7010 results in a 32-port unit being numbered from 7010
to 7041.