Specifications
56
S36 = 4, 6 LPAM, MNP, or hangup MNP or hangup
S36 = 5, 7 LAPM, MNP, or async MNP or async
S89 Timer to Control Sleep Mode
This command displays the number of seconds of inactivity (no characters sent
from the DTE, no RING) in the off-line command state before the modem places
itself into standby mode. A value of zero prevents standby mode.
Note: If a number between 1 and 4 is entered for this register, it will set the value
to 5, and the inactivity before standby will be 5 seconds. This is done for compat-
ibility with previous products which allowed time-outs down to 1 s.
Range: 0, 5-255
Default: 10
S90 Local Phone Status
This register tells the status of the local phone. It is read only.
0 = local phone on-hook
1 = local phone off-hook
S91 Line Transmit Level
This register is effective only for Japan. It specifies the line transmit level in dB
with an implied minus sign.
Range: 6-15
Default: 15
Units: 1 dB
S92 Direct Connect Transmit Level (default 20)
Sets the transmit level, in dBm for direct connect. This value may have different
settings for different phones.
S109 K56flex and V.90 Selection (default 1)
Use this register to disable 56K connections or to choose between K56flex and
V.90 protocols. The default setting (S109=1) will attempt K56flex first, then V.90,
and then V.34 depending upon the central site modem being called and your phone
line conditions. (see the next page for listing.)