Specifications

39
modems nonvolatile memory. The ATZ command or a powerup reset of the mo-
dem restores this profile.
Result Codes:
OK n = 0
ERROR Otherwise
&Yn Select Stored Profile for Hard Reset
This command does not change the behavior of the modem but is included for
compatibility with applications that issue the &Y0 command:
&Y0: Select stored profile 0 on powerup
&Y1: ERROR.
Result Codes:
OK n = 0
ERROR Otherwise
&Zn=x Store Telephone Number
This command is used to store up to four dialing strings in the modems nonvola-
tile memory for later dialing. The format for the command is &Zn = stored num-
ber where n is the location 0?3 to which the number should be written. The dial
string may contain up to 40 characters. The ATDS = n command dials using the
string stored in location n.
Result Codes:
OK n = 0, 1, 2, 3
ERROR Otherwise
\An Select Maximum MNP Block Size
The modem will operate an MNP error corrected link using a maximum block
size controlled by the parameter supplied.
\AO 64 characters.
\A1 128 characters.
\A2 192 characters.
\A3 256 characters (DEFAULT).