Instruction manual
Known Limitations in Release 4.1
296-1011-220 Rel. 4.1, Doc. Rev. 07.02 4-11
Known Problems and Limitations
shelf 1/slot 9/SCC/BIC/T1 1> configure t1_trunkconfig
shelf 1/slot 9/SCC/BIC/T1 1/T1_trunkconfig> commit
shelf 1/slot 9/SCC/BIC/T1 1/T1_trunkconfig> exit
There are outstanding changes to the running configuration: Save
the running configuration as the saved configuration? [Y/N] y
CVX>
Alarm State Indication (CR 139219)
If you set the AdminState of a T3 or of an individual T1 in the T3 to disabled, the
Alarm State displayed by a show ds1 slot n command incorrectly indicates OK
for the disabled T3 or T1.
Accounting Stop Packet (CR 139223)
The Accounting Stop packet functionality should be used specifically for failed
connections that specifically have the user name set to Unknown. The Accounting
Stop functionality has been incorrectly extended to the RADIUS diagnostics
command radius -a, causing the packets to be sent to the RADIUS server with
user names of Unknown.
CVX-SS7-Session-Id-Type (CR 139231)
The CVX-SS7-Session-Id-Type attribute may appear in accounting stop and start
packets.
Login-Service Attribute (CR 139232)
The Login-Service attribute is implemented only for clearTCP connections. The
attribute shows up in other instances where it has no relevance, such as in regular
PPP calls and L2F/L2TP calls. (For clearTCP connections, the Login-Service
value of 2 (TCP Clear) is correct.)
Trunk Value Counting (CR 139250)
After a fresh reboot of the CVX switch, the show session summary command
displays a Trunk value of 100 percent. When calls are brought into the CVX
switch, the percent value changes, eventually decreasing to 0.