Upgrading to the Double-Density Hardware
1-26 296-1011-220 Rel. 4.1, Doc. Rev. 07.02
CVX Multi-Service Access Switch 4.1 Release Notes
9 Remove the flash card from the redundant SCC and place it into the
new redundant SCCI-I, if used.
10 Apply power to the CVX switch.
After the boot up sequence is complete, verify functionality of all new
hardware and software and overall operation of the CVX switch.
11 From a console session, type felf bepbr.elz.
If your CVX switch has a redundant SCC you will need to execute the
command for the redundant SCC. To do this, type vshell -r, then type
felf bepbr.elz. Type cold to reboot the redundant SCC. Exit the
redundant SCC by pressing CTRL-C.
12 On the double-density DAC cards, provision the new DS1 and DS3
lines as needed onto the new hardware.
13 Increase the number of VPOPs or increase the IP pools so that you
have enough IP addresses to assign to the increased number of calls.
Note: Ensure that the MAC port count is equal to or greater than the DS0
count enabled.
Step Action