Change Motion Detection profile: This will switch the profile of the selected Motion Detection 
region from Runtime profile to Event profile. The profile will return to runtime settings at the end of 
this event. You may program one motion detection region to be disabled at runtime, but enable it 
with event handler under some circumstances.   
Send URL command: Select the URL command to include in the response set. Two different 
commands will be sent at the time when the event is triggered and un-triggered. For example, 
going  to  a  preset  point,  if  the  device  is  a  PTZ  camera,  and  there  are  preset  points  already 
configured in PTZ setup page, then you may include this in the response section of the event rule 
by using Send URL Command method. It is possible to let the camera return to another preset 
point at the end of the event. 
Change to Day / Night Mode  (Selected models  only): For some models,  you may force the 
Camera into Day or Night mode. The camera will return to its previous setting (whether auto or 
forced day/ night) upon the end of the event. 
After  changing  any of the  items  above,  press  Apply  to save  the  changes.  The  Reset  button 
undoes the changes that had just been made but not Applied yet. 