Installation guide
www.acti.com
ENR-1000 System Administrator’s Manual
13
Reset to Factory Default
By resetting this device, all your system settings will return to factory default, while the
previous recording files and system logs are still kept on storage disks. It is strongly
recommended that you back up previous
settings by Backup function before resetting
to factory default.
1. To begin, please turn off the device
first.
2. Press down the Power Button to
boot up the device, and immediately
press and hold the Reset Button
with a pin or clip, the red System LED
will light up for about 2~3 seconds,
and you may release the Reset Button as the red light is off.
The device will enter the resetting process.
After the device automatically reboots, the resetting process is done and you may log in.
LED Indicators
The LED indicators on front panel show the current device status:
Item
Indicator Status
Color
Description
Power LED
Solid
Blue
The device power is on.
System Status
LED
Lights up for
three seconds
after Reset
Button is pressed
Red
The system resetting process is
initializing.
Solid
The system service is running.
HDD LED
Flashing
Green
The hard disk is recording.