6:Torque limit When using the values entered in
C03 or C05, the maximum current of
the inverter is exceeded. Enter lower
torque limits.
Correct the parameterization. Switch the device on/off or
programmed acknowledge-
ment
7:B26:SSI-Slave SSI slave must not be used as a mo-
tor encoder (synchronisation prob-
lems).
Correct the parameterization. Switch the device on/off or
programmed acknowledge-
ment
8:C01>B83 C01 must not be larger than B83. Correct the parameterization. Switch the device on/off or
programmed acknowledge-
ment
9:E102/E103 faulty An attempt was made to apply a
master position via the IGB but the
required E102 and E103 parameters
are not available.
Correct the parameterization. Switch the device on/off or
programmed acknowledge-
ment
10: G104<->G27 A master position is sent via the IGB
Motionbus (i.e. G104 is not set to
0:inactive ) but the 0:inactive and
6:IGB settings valid for this case
could not be detected in G27.
Correct the parameterization. Switch the device on/off or
programmed acknowledge-
ment
Cause Description Measure Acknowledgement