Technical data
Diagnosis
Operating Manual
76ID 442281.00
WE KEEP THINGS MOVING
13
13.3.10 40:Invalid data
Resolution Level Response Fault counter
A data error was detected when initializing
the non-volatile memory.
Malfunc-
tion
The inverter cannot be enabled. Z40
Cause Description Measure Acknowledgement
1:Error Low level write/read error or timeout. The inverter must be sent in for re-
pair. Please contact our service de-
partment, see section 1.4 Further
support
can not be acknowl-
edged
2:blockMiss unknown data block
3:dataSecurity Block has no data security.
4:CheckSum Block has a check sum error.
5:R/O Block is r/o.
6:readErr Start-up phase: Block read error
7:blockMiss Block not found
17:Error Low level write/read error or timeout.
18:blockMiss unknown data block
19:dataSecurity Block has no data security.
20:CheckSum Block has a check sum error.
21:R/O Block is r/o.
22:readErr Start-up phase: Block read error
23:blockMiss Block not found.