Technical data
Parameterizing axis management
Operating Manual
ID 442281.00
WE KEEP THINGS MOVING
39
8
8 Parameterizing axis management
This section describes axis management. Management of the axes takes place 
in the global area. Management means the unique control of a maximum of one 
axis. All axes can be deactivated. The display of the inverter shows which axis is 
active or whether there is an active axis.
The axes can be combined with motors in different ways. For instance, when only 
one motor is connected directly to the inverter, several axes can be allocated with 
applications and switched. In this case, the axes function like parameter sets (see 
Figure 8 1).
Fig. 8-1: Using the axes as parameter records
Information
The axis can only be switched when the enable has been switched off 
and E48 device state is not 5:fault. The option startup disable ASP 5001 
may not be active when an axis is switched!
Axis 1
(= ”parameter set 1”)
Axis management
Axis 2
(= “parameter set 2”)
Axis 3
(= “parameter set 3”)
Axis 4
(= “parameter set 4”)
no axis active!
ESC
X3
I/O
#
Motor 1










