Technical data

Parameterizing brake data
Operating Manual
ID 442281.00
WE KEEP THINGS MOVING
37
7
The current motor torque is stored in the setting F08 = 1:active while the brake is
activated. This torque is built up again after the brake is released. If F08 is set to
2:Do not save torque, only the motor flux is built up while the brake is being re-
leased.
When F08 is set to 0:inactive, the brake is activated with system enable A900.In
this case, brake release and application times are ignored.
Use motors with brakes from STÖBER ANTRIEBSTECHNIK GmbH & Co. KG.
Look up the correct values for F07 and F06 in the catalogs. If you use a servo mo-
tor with EnDat
®
encoder, F07 and F06 will be automatically read from the elec-
tronic nameplate each time the device is started.
If you have connected two brakes to an SDS 5000, enter the greater value in F06
and F07. Also set in B07= 1:arbitrary setting, so that the electronic name plate
does not automatically overwrite these parameters.
To accommodate for the physical factors of motor and brakes, parameterize the
parameter F08 > 0. Please note that the assistant page Holding brake is displayed
dynamically as a function of the control mode selected.
7In F06, enter the time that the brake takes to be released (control modes B20
= 2:vector control and 64:servo-control).
8 Transfer the parameters to the inverter and save them there.
9 Turn the inverter off and on again.
Ö You have parameterized brake activation.