5.2 Direct entry in the parameters
The specifications of motors which do not have an electronic nameplate and can-
not be selected in the configuration assistant must be entered in the parameter
list (e.g. motors of other manufacturers and special motors). Depending on the
motor type and the type of control, different parameters must sometimes be used.
Information
In control type 0:V/f-control, no current or torque limitation occurs. Also
connection to a rotating motor is not possible (capture).
Direct entry of the motor data
1 Open the configuration assistant in POSITool.
2 Go to step 5 motor selection:
3 Select a motor similar to your motor from the list of motors.
4 Close the assistant.
5 In POSITool select the parameter list.
6In B20 control mode, select the necessary control mode.
7In B06 motor-data, enter 1:User defined