Technical data

Parameterizing motor data
Operating Manual
ID 442281.00
WE KEEP THINGS MOVING
29
5
5 Parameterizing motor data
Specifications and control mode must be given so that the motors can be con-
trolled correctly. There are several ways to enter the motor data:
Selection of a STÖBER standard motor in the configuration assistant.
Direct entry in the parameter lists for motors from other manufacturers or spe-
cial motors.
5.1 Selection in the configuration assistant
Proceed as shown below to select a STÖBER standard motor in the configuration
assistant:
Information
Refer to the inverter's configuration manual for information on connec-
tion.
Information
The number of parameters displayed on the inverter and in the POSI-
Tool depends on the access level set in the parameters. The access
level in the drive controller can be set in the parameter A10 and in the
POSITool in Extra/Change access level.
Information
In control type 0:V/f-control, no current or torque limitation occurs. Also
connection to a rotating motor is not possible (capture).
Selecting the motor in the configuration assistant
1 Open the configuration assistant in POSITool.
2 Proceed up to step 5 motor selection.
3 Select your required motor from the list of motors (e.g. asynchronous motor
112 M Y 4 kW).
4 Close the assistant.
5 In POSITool select the parameter list and in parameter B20 enter the neces-
sary control mode (e.g. 1:Sensorless vector control).
6 Go online and transfer the settings to the inverter.
7 Save the settings with A00 Save values.
Ö The motor data and the control mode are correctly entered.