Technical data
3
Commissioning an inverter
ID 442281.00
WE KEEP THINGS MOVING
Operating Manual
16
5 Switch on the enable.
Ö The inverter is in the 4:Enabled device state.
Ö You have placed the inverter in operation.
Device state
of the inverter
Power
power unit (X10)
1
0
t
24 V power
control unit (X11)
1
0
t
1
0
t
1
0
t
Enable
(X1.4, X1.3)
1
1
0
0
t
t
Response message
enable ( )A900
Startup
1:Switchon
disable
2:Ready to
switch on
4:Enabled
relay 1
(X1.1, X1.2)
1
0
t
Activation ASP 5001
(X12.3, X12.4)
Response message
ASP 5001 ( )E67
1
0
t
24 V power
accessory
1
0
t
DC link charging
relay ( )E14
>0
1.
2.
3.
4.
5.