Technical data

Diagnosis
Operating Manual
109ID 442281.00
WE KEEP THINGS MOVING
13
13.3.48 *ConfigStartERROR unknown hiding
13.3.49 no configuration paramodul error
When displaying no configuration paramodule error, the device start-up is ended and an error was detected by the Paramodule during start-up.
Note also the events in section 13.3.36 *ParaModul ERROR:update firmware! to 13.3.39 *ParaModul ERROR: ksb write error
Alternating to the event display, STÖBER ANTRIEBSTECHNIK appears.
13.3.50 no configuration start error
When displaying no configuration start error, the device start-up is ended and an error was detected when starting the configuration. Note also
the events in section 13.3.40 *ConfigStartERROR parameters lost to 13.3.48 *ConfigStartERROR unknown hiding
Alternating to the event display, STÖBER ANTRIEBSTECHNIK appears.
13.3.51 configuration stopped
When displaying configuration stopped, the current configuration was stopped. Apply a configuration or switch the inverter off and on again so
that the previous configuration can be loaded from the Paramodule.
Resolution Level Response
The versions of configuration and firmware
do not match.
The configuration does not start.
Possible cause Test Measure Acknowledgement
The configuration saved in the Para-
module originates from a newer in-
verter firmware that knows more hide
functions (hide parameters that
should be visible depending on other
parameters).
Apply a suitable configuration or firm-
ware via POSITool.