Technical data
Diagnosis
Operating Manual
108ID 442281.00
WE KEEP THINGS MOVING
13
13.3.46 *ConfigStartERROR unknown post-wr
13.3.47 *ConfigStartERROR unknown pre-rd
Resolution Level Response
The versions of configuration and firmware
do not match.
— The configuration does not start.
Possible cause Test Measure Acknowledgement
The configuration saved in the
Paramodule originates from a
newer inverter firmware that
recognises more PostWrite
functions.
— Apply a suitable configuration or firm-
ware via POSITool.
—
Resolution Level Response
The versions of configuration and firmware
do not match.
— The configuration does not start.
Possible cause Test Measure Acknowledgement
The configuration saved in the
Paramodule originates from a
newer inverter firmware that
recognises more Pre-read
functions (mapping of firm-
ware parameters to configura-
tion parameters).
— Apply a suitable configuration or firm-
ware via POSITool.
—