13.3.38 *ParaModul ERROR: Checksum error
13.3.39 *ParaModul ERROR: ksb write error
Resolution Level Response
A checksum error was detected when load-
ing from the Paramodule.
— The configuration does not start.
Possible cause Test Measure Acknowledgement
Memory bit dumped. — Apply a suitable configuration via
POSITool and then save it (A00)
—
Resolution Level Response
An error was detected when writing the con-
figuration in the configuration memory.
— The configuration does not start.
Possible cause Test Measure Acknowledgement
Faulty flash memory. — Replace the Paramodule. —
The configuration is too
large for the configura-
tion memory.
• Apply a suitable configuration via
POSITool and then save it (A00)
• Replace the Paramodule.