Hardware Manual Table of Contents Precautions 3 Safety Instructions ........................................................................... 5 Introduction 6 List of Models.................................................................................... 6 Package Contents............................................................................. 7 Physical Description ........................................................................
Hardware Manual Precautions Read these instructions Read all the safety and operating instructions before using this product. Heed all warnings Adhere to all the warnings on the product and in the instruction manual. Failure to follow the safety instructions given may directly endanger people, cause damage to the system or to other equipment. Servicing Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards.
Hardware Manual Federal Communications Commission Statement This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Hardware Manual Safety Instructions Cleaning Disconnect this product from the power supply before cleaning. Accessories and Repair Parts Use only the accessories and repair parts recommended by the manufacturer. Using other attachments not recommended by the manufacturer may cause hazards. Water and Moisture Install other devices (such as PoE injector, alarm, etc.) that will be used with the camera in a dry place protected from weather. Servicing Do not attempt to service this product yourself.
Hardware Manual Introduction List of Models This hardware manual contains the following models: E38 2MP Mini Bullet with D/N, Adaptive IR, Extreme WDR, SLLS, Fixed lens 6 www.acti.
Hardware Manual Package Contents Camera Mounting Screw Kit Drill Template Drill Template Cable Gland Washer Quick Installation Guide Warranty Card 7 www.acti.
Hardware Manual Physical Description Item 1 Memory Card Slot Description Insert a memory card into this slot for local recording purposes. See How to Install / Remove the Memory Card (Optional) on page 16 for more information. NOTE: Supports microSDHC only. 2 Ethernet Port Connects to a network using a standard Ethernet cable. 3 Reset Button Restores the factory default settings of the camera. Resetting the camera must be done while the power is on.
Hardware Manual Installation Procedures If there is a need to install a memory card for local storage recording, insert the memory card to the camera first before mounting the camera. See How to Install / Remove the Memory Card (Optional) on page 16 for detailed instructions. Step 1: Install the Camera 1. Mark the screw holes or attach the bundled drill template on the target surface.
Hardware Manual 4. Loosen the knob to adjust the camera tilt and orientation. 5. Adjust the camera angle and orientation. or Sample of Wall Installation Sample of Ceiling Installation 6. Tighten the knob to fix the tilt angle position. or 10 www.acti.
Hardware Manual Step 2: Connect and Manage the Cable The camera and the pre-installed network cable, “pigtail”, are resistant to salt, water, weak acid, alcohol, oil, grease and other common solvents. If the camera will be installed indoors, simply connect the network side cable to the camera Ethernet port. However, if the camera will be installed outdoors, ensure that the cable connection and the network side cable itself are also protected from different environmental factors.
Hardware Manual 3. Insert the clamping nut into the Ethernet cable (without connector). 4. Insert the cable through the gland body. 5. Attach the RJ-45 connector to the cable. For pin mapping and detailed instructions, see How to Attach the RJ-45 Connector on page 22 for detailed information. 6. Connect the RJ-45 connector to the camera connector. 12 www.acti.
Hardware Manual 7. Attach the gland body to the camera connector. 8. Attach the clamping nut to the gland body to complete the cable solution. NOTE: Make sure the clamping nut is tightly attached to the cable gland body and the sealing insert is squeezed tightly. 13 www.acti.
Hardware Manual Step 3: Connect to Network Connect the other end of the network cable to a PoE switch or injector. Then, connect the switch or injector to a network, PC, and a power source. See Power-over-Ethernet (PoE) connection example below.
Hardware Manual Other Adjustments and Accessories This section describes the procedures in preparing the camera for corridor viewing angle, installing a memory card, resetting the camera, and attaching Ethernet cable connectors. How to Position Camera for Corridor View Format The camera supports the following viewing format: Horizontal: The camera has a wider viewing angle horizontally. Corridor: The camera has wider viewing angle vertically.
Hardware Manual How to Install / Remove the Memory Card (Optional) 1. Remove the screw holding the sunshield. 2. Remove the sunshield. 3. Twist to open the front cover. 16 www.acti.
Hardware Manual 4. Insert the memory card with the metal contacts facing down the lens. NOTE: It is recommended to retain the silicon bag inside the cover to keep the interior parts dry. 5. Tightly close the camera front cover. 6. Attach the sunshield. Horizontal Viewing Angle Corridor Format Viewing Angle NOTE: There are three (3) holes in which to attach the set screw, use any one of them depending on the preferred viewing angle.
Hardware Manual 7. Attach the set screw to secure the sunshield. How to Remove the Memory Card In case there is a need to remove the card, make sure to access the camera Web Configurator to safely “unmount” the card first (see the camera Firmware Manual for more information). Once unmounted from the firmware, simply pull the card from the slot. 18 www.acti.
Hardware Manual How to Reset the Camera The camera has a Reset button that can be used to restore the camera to its factory default settings when the need arises.
Hardware Manual 3. Twist to open the front cover. 4. Using a pointed object, press and hold the Reset button for at least five (5) seconds or until the Power LED lights up. NOTE: It is recommended to retain the silicon bag inside the cover. 5. Tightly close the camera front cover. 20 www.acti.
Hardware Manual 6. Attach the sunshield. Horizontal Viewing Angle Corridor Format Viewing Angle NOTE: There are three (3) holes in which to attach the set screw, use any one of them depending on the preferred viewing angle. The middle hole is used for horizontal view format and the two (2) others are for corridor format. 7. Attach the set screw to secure the sunshield. 21 www.acti.
Hardware Manual How to Attach the RJ-45 Connector 1. Prepare the following tools: a. RJ-45 connector b. Crimping tool c. Scissors 2. Cut about one (1) inch into the plastic sheath from the end of the cable. 3. Unwind the wires and arrange them according to the color sequence below. This side up 1 Stripe Orange 2 Orange 3 Stripe Green 4 Blue 5 Stripe Blue 6 Green 7 Stripe Brown 8 Brown 4. Straighten out the wires and use the scissors to make a straight cut ½ inch from the cut end.
Hardware Manual 5. With the RJ-45 connector tab facing down, push down the wires into the connector all the way to the end. 6. Place the connector into the crimping tool, and cinch down to secure the RJ-45 connector to the Ethernet cable. 23 www.acti.
Hardware Manual Accessing the Camera Configure the IP Addresses In order to be able to communicate with the camera from your PC, both the camera and the PC have to be within the same network segment. In most cases, it means that they both should have very similar IP addresses, where only the last number of the IP address is different from each other. There are 2 different approaches to IP Address management in Local Area Networks – by DHCP Server or Manually.
Hardware Manual By double-clicking with the left mouse on the camera model, it is possible to automatically launch the default browser of the PC with the IP address of the target camera filled in the address bar of the browser already. If you work with our cameras regularly, then there is even a better way to discover the cameras in the network – by using IP Utility.
Hardware Manual Using the Default Camera IP Address If there is no DHCP server in the given network, the user may have to assign the IP addresses to both PC and camera manually to make sure they are in the same network segment. When the camera is plugged into network and it does not detect any DHCP services, it will automatically assign itself a default IP: 192.168.0.100 Whereas the default port number would be 80.
Hardware Manual Manually adjust the IP addresses of multiple cameras: If there are more than 1 camera to be used in the same local area network and there is no DHCP server to assign unique IP addresses to each of them, all of the cameras would then have the initial IP address of 192.168.0.100, which is not a proper situation for network devices – all the IP addresses have to be different from each other.
Hardware Manual Access the Camera Now that the camera and the PC are both having their unique IP addresses and are under the same network segment, it is possible to use the Web browser of the PC to access the camera. You can use any of the browsers to access the camera, however, the full functionality is provided only for Microsoft Internet Explorer.
Hardware Manual The following examples in this manual are based on Internet Explorer browser in order to cover all functions of the camera. Assuming that the camera’s IP address is 192.168.0.100, you can access it by opening the Web browser and typing the following address into Web browser’s address bar: http://192.168.0.100 Upon successful connection to the camera, the user interface called Web Configurator would appear together with the login page.
Copyright © 2015, ACTi Corporation All Rights Reserved 7F, No. 1, Alley 20, Lane 407, Sec. 2, Ti-Ding Blvd., Neihu District, Taipei, Taiwan 114, R.O.C. TEL : +886-2-2656-2588 FAX : +886-2-2656-2599 Email: sales@acti.