User manual

(1) Remove the dome
Take a cotton cloth and remove the transpar-
ent dome by turning it in counter-clockwise
direction.
(2) Insert the lens units and mount the central
lens screw
Remove the center lock screw and the
washer. Insert the lens units into the seatings.
Insert the lock screw with a washer into the
center of the camera and gently tighten it to
hold the lens units in place.
Caution: Avoid over-tightening the screw as
this might damage the camera housing.
(3) Connect the ribbon cables to the lens units
Connect the ribbon cables marked L and R
according to the
Image Sensor Combination
table (opposite page) to the installed lens
units.
Example: A D12D-Night always takes the L
ribbon cable on the (BW) lens mount, the R
ribbon cable is always connected to the
(color) lens mount (see
Image Sensor Combi-
nation
table on the opposite page).
While doing so, make sure that the lens unit's ribbon cable connectors are
always pointing upwards into the dome. This will ensure that the lenses
can be positioned freely later on, without putting any strain on the ribbon ca-
bles. Make sure that the ribbon cables are running properly along the inside
of the dome's rim. The ribbon cables must not obstruct the line of vision of
the lenses!
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
43/124
D12 Camera Manual Part 1
Dismount the dome by
turning it counter-clock-
wise