Step 2: Press and continue to hold the Reset Button (with a sharp tipped object, like a pen.)   
Step 3: Reconnect the power cable while continuing to hold the reset button. The red 
Power LED light will flash on for 3 second first, turn off for about 15 seconds, flash on for another 
second and turn off again. By this time the reset to default operation is already completed. This 
will take around 20 seconds from power up. You may then release the reset button. This 
length of time fluctuates slightly with the environment. The Power LED light will come back on 
and stay on after a few more seconds. The unit will start up with factory default settings 
automatically. 
On (3s)
On 
1s
Power On
About 20 Seconds
Stay On
Off (about 15s)
Off (10~15s)
Restore to Default 
Complete
4)  Digital Input / Output * 
The IP PoE Fixed Dome Camera supports Digital Input / Output with terminal block connections. 
Pushing down the tab above will reveal a small slot for you to insert the end of wire. Release the 
tab and the wire will be fastened by the internal spring. The connection pins are as shown in this 
image: 
Digital Input / Output include the following: 
•1 transistor output - For connecting external devices such as relays and LEDs. Connected 
devices can be activated by Output buttons on the Live View page or through video management 
software.   