•1 Digital Input - An alarm input for connecting devices that can toggle between an open and 
closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. The device 
will detect the change in digital input and transmit the signal to video surveillance servers. 
Terminal Pin Define is described as below: 
* Available only for device versions with enhancements 
5)  Audio Input / Output 
The IP PoE Fixed Dome Camera supports Audio input / output with terminal block connections. 
Pushing down the tab above will reveal a small slot for you to insert the end of wire. Release the 
tab and the wire will be fastened by the internal spring. The connection pins are as shown in this 
image: 
Pin Name 
Description 
Spec 
DIO PW 
Electrically connected in parallel with the con-
nector for the power supply, this pin provides an 
auxiliary connector for mains power to the unit. 
This pin can also be used to power auxiliary 
equipment, with a maximum current of 100mA. 
Voltage: 12V DC, 
Max: 1.2W   
DIO GND 
Ground 
Description 
DO 
(Transistor 
Output) 
Uses an open-collector NPN transistor with the 
emitter connected to the GND pin. If used with an 
external relay, a diode must be connected in 
parallel with the load, for protection against 
transient voltages. 
Max load = <100mA 
Max voltage = 24V 
DC (to the 
transistor) 
DI   
(Digital 
Input) 
Connect to GND to activate, or leave floating (or 
unconnected) to deactivate. 
Must not be 
exposed to 
voltages greater 
than 30V DC. 