User Guide
ACTsmart Operating and Installation Manual Rev. 1.2
6
ACTsmart Operation
The ACTsmart family consists of Proximity Only (ACTSmart 1070), Pin and Proximity (ACTsmart
1080) and PIN Only (ACTsmart 1090) units. Each ACTsmart can operate in standalone mode. Up to
8 ACTsmart devices can be connected on a RS485 network. The ACTsmart supports 500 users. Each
unit is contained in a rugged polycarbonate housing, with stainless steel keys and potted electronics,
allowing for indoor and outdoor installation.
Programming the unit is achieved via keys and feedback through the unit LED and the buzzer. For
quick and easy installation, the ACTsmart has a default configuration, which is suitable for most
installations requiring only the Programming Code to be changed, and the cards programmed into the
system. Using the Card Batch method, cards can be programmed into the ACTsmart very quickly.
ACT recommends that the user keep track of the Cardholders and PIN users on the system by using
the User List at the end of the manual. Make copies of this sheet and enter all User details on it. This
will allow users to be deleted later on, even if a card is lost or a user forgets their PIN code. Additional
User Lists can be downloaded from the resource section of our website at www.accesscontrol.ie
To improve security, PIN codes may be up to 8 digits in length. Normally only card users are allowed
access through the ACTsmart PIN and Prox unit. For maximum security, the unit may be programmed
to require all users to enter a PIN code after presenting a card. For lower security applications, another
programming options allows access to PIN only users. A duress code feature is also available
The built-in inputs and outputs are programmable, allowing the ACTsmart to be used in a wide variety
of applications from simple door access, to cash offices and fire exits. Each unit also has built-in
tamper monitoring for improved security.
ACTsmart Programming
Press the
✘
button followed by the programming code (initially 9999). The LED will flash amber
while in programming mode. If
✘
is pressed at any time or no key is pressed within 30 seconds,
programming mode is exited. If the LED flashes green during programming, then a card presentation
is expected. If the LED flashes red, then a keypress is expected. If the ACTsmart is busy performing
a task, (Eg. Defaulting memory, adding cards), the buzzer will sound an elongated tone.
Note: In most Programming Menus there is a step that is marked (optional)*. This setting only applies
to a Networked System (see Programming a Network System).