Technical data
Technical description
30 – EN ACT 600 – 5000
7.16 Electronic drainer
This drain consists of a condensate accumulator where a capacitive sensor continuously checking liquid
level is placed: as soon as the accumulator is filled, the sensor passes a signal to the electronic control and
a diaphragm solenoid valve will open to discharge the condensate. For a complete condensate discharge
the valve opening time will be adjusted exactly for each single drain operation. No condensate strainers are
installed. No adjusting is required. A service valve is installed before the electronic drain in order to make
check and maintenance easily. At dryer start-up verify that this valve is open.
Control panel
Power Led On - drainer ready to work / supplied
Alarm Led Blinking - drainer in alarm condition
TEST Button Discharge test (keep pushed for 2 seconds)
Troubleshooting
Only qualified personnel should perform troubleshooting and or maintenance
operations.
Prior to performing any maintenance or service, be sure that :
no part of the machine is powered and that it cannot be connected to the mains
supply.
no part of the machine is under pressure and that it cannot be connected to the
compressed air system.
maintenance personnel have read and understand the safety and operation
instructions in this manual.
SYMPTOM POSSIBLE CAUSE - SUGGESTED ACTION
No led lighting up. Verify that the system is powered.
Verify the electric wiring (internal and/or external).
Check internal printed circuit board for possible damage.
Pressing of Test button, but
no condensate discharge.
The service valve located before the drain is closed - open it.
The dryer is not under pressure - restore nominal condition.
Solenoid valve defective - replace the drain.
The internal printed circuit board is damaged - replace the drain.
Condensate discharge only
when Test button is pressed.
The capacitive sensor is too dirty - open the drain and clean the sensor
plastic tube.
Drain keeps blowing off air. The diaphragm valve is dirty - open the drain and clean it.
The capacitive sensor is too dirty - open the drain and clean the sensor
plastic tube.
Drain in alarm condition. The capacitive sensor is too dirty - open the drain and clean the sensor
plastic tube.
The service valve located before the drain is closed - open it.
The dryer is not under pressure - restore nominal condition.
Solenoid valve defective - replace the drain.
NOTE : When the drain is in alarm condition, the diaphragm solenoid valve will open 7.5 sec every 4
min.