Technical data

Technical description
28 – EN ACT 600 – 5000
7.15.6 How to show the alarm memory – LOG Menu
The log menu is the list of the last 10 alarms (only alarms, not service warning). They appear in
chronological order (LIFO logic).
With dryer ON or OFF and not in other menus, press
log
for at least 1 second to enter the log menu.
Access to the log menu is confirmed by message
(L01) on the display (first parameter of menu). Use
the arrows
and to move to following/previous (L01 … L10). Press
log
to show the selected log
value. Alternatively the parameter that generated the alarm and the hours of operation of the machine when
the alarm tripped are shown. Press
log
again to return to the log list.
Press
ESC
to exit log menu (if no button is pressed after 2 minutes the menu is exited automatically).
NOTE: an empty position in the log list is displayed by the message
.
7.15.7 How to control dryer with remote control
The DMC24 can be easily controlled using 2 digital inputs connected to terminals 1, 2 and 3 (see electric
diagram).
Close the contact between the terminals 2 and 3 to enable the remote control, the led
turns on and
it is no longer possible to switch the dryer ON or OFF from local panel (the condensate drain test is possible
and access to info and log menus).
Having contact between terminals 2 and 3 closed, close the second contact between the terminals 1 and 2
to switch ON the dryer. Open the contact between the terminals 1 and 2 to switch OFF the dryer.
Use dry contacts only (potential free) suitable for low voltage. Assure an adequate
isolation of potentially dangerous powered parts.
CAUTION:
AUTO-RESTART / REMOTE ON-OFF
THE DRYER MAY POWER UP WITHOUT BEING ACTED UPON.
THE USER WILL BE RESPONSIBLE FOR THE INSTALLATION OF PROPER PROTECTIONS
FOR POSSIBLE SUDDEN POWER RESTORATION TO THE DRYER.
7.15.8 Operation of the failure / alarm dry contact (potential free)
The DMC24 is equipped with a dry contact (potential free) to display failure and/or alarm conditions.
54 6
Dryer powered and no service warning or alarm (active and not yet reset) displayed.
654
Dryer not powered or service warning or alarm (active and not yet reset) displayed.
7.15.9 Connection to serial line
The DMC24 can be connected to a supervision serial line, remote control or download of log file (memory)
of alarms.
Contact your distributor or service centre for more information.