Technical data

Start-up
14 – EN ACT 600 – 5000
4.9 Condensate drain
The condensate is discharge at the system pressure.
Drain line should be secured.
Never point the condensate drain line towards anybody.
The dryer comes already fitted with an electronic condensate drainer.
Connect and properly fasten the condensate drain to a collecting plant or container.
The drain cannot be connected to pressurized systems.
Don’t dispose the condensate in the environment.
The condensate collected in the dryer contains oil particles released in the air by the compressor.
Dispose the condensate in compliance with the local rules.
We recommend to install a water-oil separator where to convey all the condensate drain coming
from compressors, dryers, tanks, filters, etc.
5 Start-up
5.1 Preliminary operation
Verify that the operating parameters match with the nominal values stated on the data nameplate
of the dryer (voltage, frequency, air pressure, air temperature, ambient temperature, etc.).
This dryer has been thoroughly tested, packaged and inspected prior to shipment. Nevertheless, the unit
could be damaged during transportation, check the integrity of the dryer during first start-up and monitor
operation during the first hours of operation.
Qualified personnel must perform the first start-up.
When installing and operating this equipment, comply with all National Electrical Code and any
applicable federal, state and local codes.
Who is operating the unit is responsible for the proper and safe operation of the dryer.
Never operate equipment with panels removed.