System information

General Reference Guide eWON Configuration
RG-001-0-EN ver 1.5 eWON® - 20/03/2009 - ©ACT'L sa Page 42
3.3.4.2.4 VPN
Figure 34: VPN Global setup page
Control Description
Diagnosis level
Choose the level of diagnosis reported in the “Real Time Log” on page 161.
Level could: None, Low, Medium or High
Port In
The TCP Port number where eWON will listen all incoming VPN traffic.
port <> 0 Only this port could be use for incoming VPN traffic.
0 = default behavior
• If VPN is initiated by the eWON (contacting eSync), the incoming port will be set dynamically
• If VPN is initiated by an external source (eCatcher), the eWON listens on the port 1194
(hardcoded)
Port Out The TCP Port number where eWON will send all outgoing VPN traffic (default 1194)
‘Keep alive’ interval
Set at which interval (in second) the eWON send a short packet to maintain the connection
opened.
VPN Driver Mode
Select the VPN driver mode you need. Available mode are:
• TAP
• TUN
VPN Protocol