System information
General Reference Guide eWON Configuration
RG-001-0-EN ver 1.5 eWON® - 20/03/2009 - ©ACT'L sa Page 40
Primary & secondary servers
The following parameters are the same for both servers. Two different servers can be set up. This ensures that the eWON can find a way out for
PPP link if a server is down. At the startup of a connection, the primary server is always dialed first. If the connection cannot be established, the
eWON tries the second server. If it fails, then it toggles back to the primary server. This is done until the dial-out timeout is reached.
Figure 32: Modem Outgoing Server setup page
Control Description
Connection type
only present in GSM/GPRS modems.
Select the dialUp type: Remote acces connection or GPRS.
With GPRS, the Server phone number will be hidden (unused).
Server phone number
The complete phone number of the server. A coma (,) can be used to insert a pause (can be
useful i.e. if you have to go through a pabx).
User Name The User name of your ISP login for PPP link establishment.
Password The Password linked to the above login for PPP link establishment.
Require secure authentication
(CHAP)
If this box is checked, then the eWON explicitly requests CHAP authentication for the PPP
link. If the other side cannot do CHAP, no connection will be made. If this box is left
unchecked, then PAP (clear text password) is used.
Table 31: Modem Outgoing Server configuration controls