User's Manual Part 2
T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
4--58
Table 4--8. Operator Selectable Options -- Default Settings(cont)
Operator Selectable
Options
Selectable OptionData Parameter
Bank Angle Repetition BANK_ANGLE_REPETITION 1, 2, 3, 4, Infinity -- T
2
CAS
will repeat the Bank Angle
W arning based on the Bank
Angle Repetition input.
CPA Caution Alert CPA_MODE_CAUTION 1 = “TERRAIN AHEAD”,
2 = “TERRAIN CAUTION“
CPA Mode A Warning Alert CPA_MODE_A_WARNING 1 = “TERRAIN AHEAD
PULL--UP”,
2 = “TERRAIN TERRAIN
PULL--UP PULL--UP” or
3 = “Whoop, Whoop--PULL
UP”
CPA Mode B Warning Alert CPA_MODE_B_WARNING 1 = “AVOID TERRAIN”
GPWS Caution Flash
Enable
GPWS_CAUTION_FLASH_
ENABLE
Enable -- Caution lamp
flashing for the duration of
the GPWS Caution Event.
Disable -- Caution lamp
solid for the duration of the
GPWS Caution Event.
GPWS Warning Flash
Enable
GPWS_W ARNING_FLASH_
ENABLE
Enable -- Warning lamp
flashing for the duration of
the GPWS Warning Event.
Disable -- Warning lamp
solid for the duration of the
GPWS Warning Event.
Male Voice Enable MALE_VOICE_ENABLE Enable -- enables the male
alerting voice
Disable -- alerting voice is a
female voice.
Mode 1 Caution Alert MODE_1_CAUTION 1 = “Whoop, Whoop, PULL
UP” or
2=“PULLUP,PULLUP”
Mode 1 W arning Alert MODE_1_W ARNING 1 = “Whoop, Whoop, PULL
UP” or
2=“PULLUP,PULLUP”
Mode 2 Caution Alert MODE_2_CAUTION 1 = “TERRAIN, TERRAIN”
Mode 2 W arning Alert MODE_2_W ARNING 1 = “Whoop, Whoop, PULL
UP” or
2=“PULLUP,PULLUP”