User's Manual Part 2

T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
4--50
A listing of the TAWS/RWS Input Data Signals, LRUs providing those signals, their data
definitions (i.e. Analog signal type, A429 Label, etc.) and the minimum requirements that
must be met by that specific input signal in order for TAWS/RWS to function within
specification.
A. TAWS/RWS Pinout and Pin Descriptions (Non--Configurable)
This section contains the non--configurable pin assignments for the GCAM functionality
(Table 4-- 6).
Table 4--6. TAWS/RWS Non--Configurable Pinout
Pin
Designation
Signal Functional Description
RightTopPlug(RTP)
RTP--1A, --1B ARINC 453 Terrain Display Output No. 1:
(RTP --1A [A], RTP--1B [B])
A453 Output
RTP--1E, --1F ARINC 453 Terrain Display Output No. 2:
(RTP --1E [A], RTP--1F [B])
A453 Output
RTP--8G, --8H Glide Slope Low Level Deviation No. 1:
(RTP --8G [+], RTP--8H [--])
Analog ILS Input
RTP--8J, --8K Localizer Low Level Deviation No. 1:
(RTP --8J [+], RTP--8K [--])
Analog ILS Input
RTP--9C, --9D Glide Slope Low Level Deviation No. 2:
(RTP --9C [+], RTP--9D [--])
Analog ILS Input
RTP--9E, --9F Localizer Low Level Deviation No. 2:
(RTP --9E [+], RTP--9F [ --])
Analog ILS Input
RTP--14E dc Total Air Temperature Return Analog dc TAT Return
RTP--14F,
--14G, --14H
dc Altitude Rate A575/595:
(RTP--14F [Signal], --14G [Ref+], --14H [Ref--])
Analog dc A575/595
RTP--14J dc Output Reference +5 Vdc: The T
2
CAS provides a +5 Vdc
precision reference output as a
reference voltage for analog
sensors which provide a
ratio--metric output. In most
installations the reference
voltage and the signal voltage
are monitored so that the
tolerance of the reference output
is not critical. This is the
preferred method and eliminates
issues such as ground
differentials in aircraft
installations.