User's Manual Part 2

T
2
CAS / Part No. 9000000
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
34-43-20
15 Feb 2003
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
4--24
Table 4--1. TT--950/951/952 T
2
CAS Computer Unit Interface Description (cont)
Connector Pin
Designation
Functional Description
J1--20, 22 1 15 Vac Power Output: [J1--20 (H), J1--22 (C)]
These power output pins provide the 115 Vac operating power for the data loader.
The 115 Vac (H) and 115 Vac (C) interconnect wires should be shielded or twisted and
shielded with an insulating jacket over the shield. The shield should be connected to
chassis ground (J1--21).
J1--21 Chassis Ground
Connect 115 Vac power shields to this pin.
J1--23 A615A Dataloader Ethernet Input (RD+)
TA WS Ethernet 10--base--T read input
J1--24
Thru
J1--28
Spare Pins
J1--29, 30 RS--422 Recorder Data Output: [J1--29 (+), J1--30 (--)]
The RS--422 Flight Data Recorder data is output on these pins.
J1--31, 32 RS--422 Recorder Clock Output: [J1--31 (+), J1--32 (--)]
The RS--422 Flight Data Recorder internal 125k Hz internal clock is output on these pins.
J1--33,34 ARINC 429 TA/RA Display No. 1 Output: [J1--33 (A), J1--34 (B)]
This bus can be used to connect to a maintenance display. These pins are also
connected to the ARINC 600 connector on the rear of the unit (RMP--7C and --7D).
J1--35,
J1--36
Spare Pins
J1--37, 38 28 V dc Power Output: [J1--37 (HI), J1--38 (LO)]
These power output pins provide the +28 Vdc operating power for the data loader. These
pins are used only if the data loader operates from a +28 Vdc source.
J1--39 A615A Dataloader Ethernet Input (RD --)
TA WS Ethernet 10--base--T read input
J1--40 T
2
CAS RS--232 Data Input
This input is used by the TAWS, TCAS and GPS function to receive RS--232 data from a
portable maintenance terminal.
J1--41 T
2
CAS RS--232 Data Output
This output is used by the TAWS, TCAS and GPS function to transmit RS--232 data to a
portable maintenance terminal.
J1--42 TCAS RS--232 Data Input
This input is used by the TCAS function to receive RS--232 data from a portable
maintenance terminal.
J1--43 TCAS RS--232 Data Output
This output is used by the TCAS function to transmit RS--232 data to a portable
maintenance terminal.